PACS System 0.1.0
PACS DICOM system library
|
Options for Ophthalmic IOD validation. More...
#include <ophthalmic_iod_validator.h>

Public Attributes | |
| bool | check_type1 = true |
| Check Type 1 (required) attributes. | |
| bool | check_type2 = true |
| Check Type 2 (required, can be empty) attributes. | |
| bool | check_conditional = true |
| Check Type 1C/2C (conditionally required) attributes. | |
| bool | validate_pixel_data = true |
| Validate pixel data consistency (rows, columns, bits) | |
| bool | validate_ophthalmic_params = true |
| Validate ophthalmic-specific image parameters. | |
| bool | validate_laterality = true |
| Validate laterality (R/L/B) | |
| bool | strict_mode = false |
| Strict mode - treat warnings as errors. | |
Options for Ophthalmic IOD validation.
Definition at line 79 of file ophthalmic_iod_validator.h.
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::check_conditional = true |
Check Type 1C/2C (conditionally required) attributes.
Definition at line 87 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate(), and kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_ophthalmic_image_module().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::check_type1 = true |
Check Type 1 (required) attributes.
Definition at line 81 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_general_series_module(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_general_study_module(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_image_pixel_module(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_ophthalmic_image_module(), and kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_sop_common_module().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::check_type2 = true |
Check Type 2 (required, can be empty) attributes.
Definition at line 84 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_general_series_module(), kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_general_study_module(), and kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_patient_module().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::strict_mode = false |
Strict mode - treat warnings as errors.
Definition at line 99 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::validate_laterality = true |
Validate laterality (R/L/B)
Definition at line 96 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_ophthalmic_image_module().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::validate_ophthalmic_params = true |
Validate ophthalmic-specific image parameters.
Definition at line 93 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate().
| bool kcenon::pacs::services::validation::ophthalmic_validation_options::validate_pixel_data = true |
Validate pixel data consistency (rows, columns, bits)
Definition at line 90 of file ophthalmic_iod_validator.h.
Referenced by kcenon::pacs::services::validation::ophthalmic_iod_validator::validate(), and kcenon::pacs::services::validation::ophthalmic_iod_validator::validate_image_pixel_module().